HKGB Serial Vortex Flowmeter
Features:
Widely used to measure saturated steam, superheated steam,wet steam, dry steam, dry gas, wet gas, liquid, water, oil etc, any kind of liquid or gas flow rate and total flow
-
High Accuracy:+0% for pipe type and + 1.5% for insertion type
-
Compact for temperature and pressure compensation when measuring steam
-
Simple & fixed structure, no moving parts, high reliability, convenient maintenance.
HKGB Vortex Flowmeter is a kind of stress type vortex flowmeter based on the karman vortex principle to measure flow and has the advantage of high signal-to-noise ratio, high sensitivity, good zero stability. Signal processing circuit adopts microcomputer technology and packages the CPU unit, storage unit, display unit, communication unit and other function modules in the circuit board, at the same time, there are RS - 485 interface, Hart protocol, ModBus protocol for chosen. Diameter ranges of DN15~DN300, widely used to measure saturated steam, superheated steam,wet steam, dry steam, dry gas, wet gas, liquid, water, oil etc, any kind of liquid or gas flow rate and total flow.
HKGB SeriesVortex Flowmeter |
HKGB/P |
HKGB/I |
|
Wafer Type |
Flange Type |
Insertion Type |
|
Medium |
Gas/ Liquid |
||
Accuracy |
±1.0% |
± 1.5%; |
|
Repeatability |
±0.5% for gas,±0.33% for liquid |
±1.0% for gas,±0.83% for liquid |
|
Fluid Temperature |
- 40 ~+250℃+ 100~+350℃ (high temp.) |
- 40~+120℃ |
|
Size |
DN15mm~DN300mm |
DN100mm~DN3000mm |
|
Rated Pressure |
GB 1.6MPa, 2.5MPa, 4.0MPa, 6.4MPaDIN PN16, PN25, PN40JIS 10K, 20K, 40KANSI Class150, Class300, Class600 |
1.6MPa |
|
Velocity |
Gas(incl. steam): 7~55m/s (7~50m/s for DN≥200)Liquid: 0.7~5.5m/s |
||
Parts Material |
Transducer Body: 340SSBluff Body: 304SSDetecting Probe: 316SSConnecting Rod: 304SSRadiator: A-alloyGasket: High Temperature Resistance Asbestos, NBR, Graphite |
||
Relative Humidity |
5~95% |
||
Installation Type |
Wafer/ Flange |
Plug-in |
|
Protection Class |
IP65 |
||
Power |
24V DC3.6V Lithium Battery ( Local Display)Double Power Supply (24V DC, 3.6V Lithium Battery) |
||
Signal Output |
Pulse/ 4~20mA |
||
Communication |
Hart/ Modbus/ Profibus/ RS485 |
||
ElectricalConnection |
2*M20*1.5 |
||
Explosive-proof |
Flameproof Exd II BT3~6, Instrinsical Safe Exia II CT3~6 |
||
OperationEnvironment |
Environment temperature:-35~60℃ (No LCD)-5~60℃ (With LCD) |
-
Sensor adopts adaptive signal processing circuit which got the national practical new type patent certificate.
-
By lots of wave analysis of vortex flow sensor in a long time, Juns Instrument has designed the most scientific probe shape, wall thickness, height, probe rod diameter and matching piezocrystal, adopts advanced CNC to machine to ensure technical parameters of proper alignment and smooth finish etc., and with special treating process to maximatily overcome existed signal influence by intrinsic self-oscillation frequency.
-
Advanced processing equipment and technology makes meter and its components with strong generality, so will not affect accuracy and repeatability if change any parts and no need calibration.
-
Best of HKGB Intelligent Vortex Flow Sensor is piezocrystal built in bluff body to avoid fluid turbulence caused by external type, no zero drift, and high repeatability.
-
Simple & fixed structure, no moving parts, high reliability, convenient maintenance. Wide measuring range, turndown ratio can reach 10:1 in Reynolds Number 2×104 ~ 7×106.
-
Detecting element does not contact with the measured fluids directly, stable performance and long service life. High accuracy, ±1.0% for measuring liquid, and 1.5% for gas.
-
Output pulse signal and current signal directly proportional to flowrate, and have RS-485, Hart, ModBus communication for convenient computer networking.
-
Low pressure loss, just 1/4 ~ 1/2 of orifice plate.